Custom Lithium Battery Packs for UPS and Backup Power
A UPS battery must wait full for months and carry the load the moment power fails. Jetray builds custom LiFePO4 packs for UPS makers and backup power integrators, to your voltage, rack or case size and charger.
What a UPS battery has to do

- Hold charge in standby. Low self-discharge and a float charge that suits lithium.
- Deliver at once. The pack must carry the full load, including inrush, when the grid drops.
- Report its state. The UPS reads charge level, current and faults.
- Fit the case. 48 V rack packs, shelf packs or internal modules for UPS makers, in the same space as the old battery.
Lithium or lead-acid in a UPS
If your UPS has a lead-acid charger, check that its charge profile suits lithium, or let us supply a matching charger.
Voltage and layout
Your UPS inverter decides the voltage. Send the DC bus voltage, power rating and the backup time you need. We work out the cell layout and check the discharge current. Cell selection →
BMS, communication and charging
The BMS balances cells and protects against overcharge, over-discharge, over-current, short circuit and temperature.
For a UPS, the link to the inverter or monitor matters. RS485, CAN, UART and Bluetooth can be set up to your requirement. A matching charger is available. BMS design → Charger and communication →

Documents, order size and delivery

UN38.3, IEC 62133 and MSDS documents are available, with transport and certification reports for the shipment. Other standards, such as UL, depend on your market. Energy storage products can be ordered in small quantities, even a few units. Custom packs usually take one to two months. Cost and MOQ →
Points to settle before you choose a UPS pack
Load, not rating
Size the battery from the real load and the backup time, not only the UPS label.
Rack or standalone
Rack modules need set dimensions and handles. Standalone packs have more freedom.
Parallel use
If you plan to connect several packs, tell us. The BMS and wiring must allow it.
Charger match
The UPS charger must suit LiFePO4 cells, or the pack needs its own charger.
Monitoring
Decide if the UPS or a monitor needs to read battery status.
Options you can set
Mark what you want to discuss. Your picks go into the quote form below.
From first message to delivery
STEP 1Send the UPS model or voltage, load, backup time and space available.
STEP 2We propose the layout, cells and BMS, and quote.
STEP 3We build a charged sample, and you test it with your UPS.
STEP 4We adjust the pack or communication from your test notes.
STEP 5Batch production, final test and shipment with the documents you need.
Frequently asked questions
Often yes, if the voltage, size, connector and charger are matched. Send the UPS model or the battery bay size.
12 V, 24 V and 48 V are common for small and rack units. Larger units use higher voltage.
RS485, CAN, UART and Bluetooth can be set up to your requirement. Send the protocol.
We supply UPS makers, integrators and distributors. For a branded UPS, contact the maker.
Yes. Energy storage products can be ordered in small quantities.
They can be designed for parallel use. Tell us how many, so the BMS and wiring allow it.
Yes. Private label is supported.
Building UPS or backup systems?
Send the DC bus voltage, power and backup time. We reply within 24 hours.
Your ups and backup battery packs
Values from the tools above are already here. Add what you know and send.
Your message to an engineer
Fill what you know. Blank lines are fine.Goes straight to our sales engineers, the same as the quote form. Need to attach a drawing? Use the quote form or email it.
Building UPS or backup systems? Send the DC bus voltage, power and backup time.
Request a Quote→