Custom lithium battery packs for device makers · Made in Shenzhen, shipped worldwide

sale1@jetray.cnEngineer reply within 24 h
01 / 07

Medical Device Batteries

Custom lithium battery packs for portable medical devices.

Explore medical device
Not sure where your product fits? An engineer replies within 24 hours.All industries Send your spec
01 / 05

Replacement Battery Packs

Custom lithium replacement packs for lead-acid batteries and light EVs.

Explore replacement
Not sure which product fits? An engineer replies within 24 hours.All products Send your spec
Surgical Robot Battery Packs

Battery Packs for Surgical and Medical Robot Systems

A surgical robot battery must keep power steady through a procedure, report its state at all times and fail safely. Jetray designs custom lithium packs for medical robot makers. Because requirements here are strict, we review each project against your specification before we commit.

Voltage and capacityChemistryCommunication
Backup battery pack inside a surgical robot cart
Start with what you knowReply in 24 h
Made in ShenzhenShipped worldwide
UN38.3 · IEC 62133 · MSDSDocuments available
Panasonic · Samsung · LG · Molicel · EVECell brands we can offer
Samples firstBuilt and tested before the batch
OEM, ODM, private labelWe also supply distributors
Reply within 24 hoursSend your spec any time
Products

Recommended products

Packs and cells we supply for this application. Every model can be customized — tap + to add models to your inquiry list, then send one request for all of them.

View all products
23 products
What robot makers

What robot makers ask of the battery

Surgical robot battery pack: what robot makers ask of the battery
  • No power glitches. A short drop can cause erratic movement, so many systems add a battery as a backup source on the supply path.
  • Known state. The system reads charge level, voltage, current, temperature and faults from the BMS.
  • Safe failure. The pack cuts off before a cell leaves its safe range, and says why.
  • Predictable run time. The robot needs to know how long it can work.
  • Traceable documents. Buyers ask for test reports and change control.
Where the pack sits

Where the pack sits in the system

Sterilisation is a major design point. Some tool packs are removed before sterilising, and some must withstand it. If your tool pack must withstand sterilisation, send the method and cycle count, and we design and test the samples for it.

RoleWhat the battery doesPoints to check
Main power for a mobile baseDrives wheels, arms and electronicsCapacity, peak current, charging routine
Backup on the supply pathBridges a mains drop or transferSwitch-over, standby loss, charge limit
Power for a handheld toolRuns a surgical toolSize, weight, sterilisation route
What we can do

What we can do

  • 01Cells LiFePO4 for long life and stability, or Li-ion for energy density. Cell selection
  • 02BMS protection against overcharge, over-discharge, over-current, short circuit and high temperature, set from your load and confirmed on samples. BMS design
  • 03Communication CAN, UART, RS485 and Bluetooth, set up to your requirement.
  • 04Charger a matching charger.
  • 05Enclosure plastic or sheet metal, IP65 as our usual level and other levels on request. Enclosure design
  • 06Backup power path we can design the power path and switch-over for a backup role, as well as the pack.
  • 07Test equipment we test samples on our own equipment and share the results.
Documents

Documents

UN38.3, IEC 62133 and MSDS documents are available, with transport and certification reports for the shipment.

Medical device rules depend on your device and market, and we do not claim a medical quality-system certificate. Tell us the standards your design must meet, and we say plainly which ones we can support. Quality and certification

Surgical robot battery pack: documents
How to start

How to start

  • 01Send the system voltage, peak and average current, run time and the backup role of the battery.
  • 02We reply with questions and a first proposal.
  • 03We build samples. Custom battery pack samples are charged.
  • 04You test the samples in the system. Custom packs usually take one to two months.
Before you order

What to agree early on a surgical robot battery

01

Which part is battery-powered

TAP TO SEE WHY
Why it mattersA cart, a base or a backup supply each need a different pack.
02

Backup role

TAP TO SEE WHY
Why it mattersIf the pack is a backup, decide how long it must carry the load and how it switches in.
03

Data

TAP TO SEE WHY
Why it mattersThe system may need charge level and fault signals. Agree the interface.
04

Documents your customer needs

TAP TO SEE WHY
Why it mattersRules depend on the market. Tell us early which reports you need.
05

Project scope

TAP TO SEE WHY
Why it mattersConfirm the quantity and timeline so we can say yes or no honestly.
Options

Options you can set

Mark what you want to discuss. Your picks go into the quote form below.

Voltage and capacityFrom the system's load and backup time
ChemistryLiFePO4 or Li-ion NMC
CommunicationCAN, UART, RS485 or Bluetooth
CaseSheet metal or plastic, to the cart or base
ChargingMatching charger supplied
Label and packingYour brand name and model number
0 selected to discuss
Process

From first message to delivery

01

Send the system type, load, backup time and space available.

02

We tell you whether we can take the project, and propose the pack.

03

We build a charged sample, and you test it in the system.

04

We adjust from your results.

05

Batch production, final test and shipment with the documents you need.

FAQ

Frequently asked questions

Send the sterilisation method and cycle count. We design the pack for it and test the samples.

Yes, this is a common design. We size the cells and protection for the switch-over and standby needs you give us.

Yes. CAN, UART, RS485 and Bluetooth can be set up to your requirement.

UN38.3, IEC 62133 and MSDS. Medical device rules depend on your device and market.

It depends on the product. Send your quantity and we confirm.

Not always. We review each project, and tell you honestly if it is a fit.

We have our own test equipment and can provide transport and certification reports.

Get a quote

Designing a medical robot?

Send the voltage, current and backup role. We reply within 24 hours.

Your requirement

Your surgical robot battery packs

Values from the tools above are already here. Add what you know and send.

Project
Options to discuss
Where should we reply?
0%

Your message to an engineer

Fill what you know. Blank lines are fine.
Email instead

Goes straight to our sales engineers, the same as the quote form. Need to attach a drawing? Use the quote form or email it.

Scroll to Top